Ramset Gate Opener Troubleshooting

If you face with the situation when the gate of your garage does not close or does not open or “RADIO” of “EXIT” light-emitting diodes are always on and so on – look at the table below. It contains important information for owners of Ramset Gate Opener. This reliable and simple manual will help you in troubleshooting whatever the problem could appear.

Ramset Gate Opener Troubleshooting

CONDITIONCAUSESSOLUTION
No lights are ‘on’.1. Circuit breaker popped.1. Reset circuit breaker.
2. 1/2 amp. fuse blown.2. Replace 1/2 amp. fuse.
3. Power supply damaged on Control Board.3. Return Control Board for repair.
Gate moves a couple of feet and then reverses.1. E.R.D. too sensitive.
“Exit” l.e.d. is always ‘on’.1. Faulty accessory connected to the “Exit".1. Disconnect all accessories, including plug-ins, using the “Exit” input. If problem persist, contact Ramset.
“Rev loop” l.e.d. always ‘on’.1. Faulty accessory connected to the “Rev Loop”.1. Disconnect all accessories, including plug-ins, using the “Rev Loop" input. If problem persist, contact Ramset.
“Radio" l.e.d. always ‘on’.1. Stuck button on Transmitter1. Check all transmitters.
2. Faulty Receiver.2. Remove receiver.
If problem persist, contact Ramset.
Gate doesn’t open.1. Radio L.E.D. ‘On’.1. See above symptoms/solutions.
2. 10 amp. fuse blown.2. Check/replace 10 amp. fuse.
3. Opening accessory not functioning.3. Check/replace opening accessory.
Gate doesn’t close.1. No lights are On’.See above symptoms/solutions.
2. Exit, Rev Loop, Radio L.E.D.'On’.
3. 10 amp. fuse blown.3. Check/replace 10 amp. fuse.
4. Thermal/overload button popped on motor.4. Reset thermal/overload button on the back of the motor.
Gate doesn’t close automatically.1. Dip switches “A" 1-3 are all Off.,
2. Dip switch not on all the way.
Gate automatically opens, but doesn’t automatically close.1. Motor direction wrong.1. Turn on dip switch (left/right).
Radio/receiver has no range.1. Signal blocked.1. Make sure antenna is in proper position & not shorted to chassis.
2. Area not suitable for type of Receiver.2. May need to change to long range receiver.

Call service